ISO 14253-1:2017 establishes standardized decision rules for verifying the conformity or nonconformity of workpieces and measuring equipment with specifications, incorporating measurement uncertainty. It defines acceptance and rejection zones based on a default 95% confidence level, reducing disputes by clearly addressing borderline measurements. For detailed information, visit ISO.

ISO 14253-1:2017 provides general principles for the inspection by measurement of workpieces and measuring equipment. The standard covers: INTERNATIONAL STANDARD ISO 14253 1.pdf

10. Worked Example

Problem: A shaft’s diameter tolerance = (20.00 \pm 0.05\ \textmm).
Measurement uncertainty (U = 0.015\ \textmm) (95%, (k=2)). INTERNATIONAL STANDARD ISO 14253 1.pdf